Environmental specifications

Data sheet

Name
agc-150-ats-data-sheet-4921240628-uk
Product
AGC 150 ATS
Operation conditions
Operating temperature (incl. display screen) -40 to +70 °C (-40 to +158 °F)
Storage temperature (incl. display screen) -40 to +85 °C (-40 to +185 °F)
Accuracy and temperature Temperature coefficient: 0.2 % of full scale per 10 °C
Operating altitude 0 to 4000 m with derating
Operating humidity

Damp Heat Cyclic, 20/55 °C at 97 % relative humidity, 144 hours. To IEC 60255-1

Damp Heat Steady State, 40 °C at 93 % relative humidity, 240 hours. To IEC 60255-1

Change of temperature 70 to -40 °C, 1 °C / minute, 5 cycles. To IEC 60255-1
Protection degree IEC/EN 60529
  • IP65 (front of module when installed into the control panel with the supplied sealing gasket)
  • IP20 on terminal side
Vibration
Response:
  • 10 to 58.1 Hz, 0.15 mmpp
  • 58.1 to 150 Hz, 1 g. To IEC 60255-21-1 (Class 2)
Endurance:
  • 10 to 150 Hz, 2 g. To IEC 60255-21-1 (Class 2)
Seismic vibration:
  • 3 to 8.15 Hz, 15 mmpp
  • 8.15 to 35 Hz, 2 g. To IEC 60255-21-3 (Class 2)
Shock

10 g, 11 ms, half sine. To IEC 60255-21-2 Response (Class 2)

30 g, 11 ms, half sine. To IEC 60255-21-2 Withstand (Class 2)

50 g, 11 ms, half sine. To IEC 60068-2-27, test Ea

Tested with three impacts in each direction in three axes (total of 18 impacts per test)

Bump

20 g, 16 ms, half sine IEC 60255-21-2 (Class 2)

Tested with 1000 impacts in each direction on three axes (total of 6000 impacts per test)

Galvanic separation

CAN port 2 (CAN B): 550 V, 50 Hz, 1 minute

RS-485 port 1: 550 V, 50 Hz, 1 minute

Ethernet: 550 V, 50 Hz, 1 minute

Analogue output 51-52 (GOV): 550 V, 50 Hz, 1 minute

Analogue output 54-55 (AVR): 3000 V, 50 Hz, 1 minute

Note: No galvanic separation on CAN port 1 (CAN A) and RS-485 port 2

Safety

Installation CAT. III 600 V

Pollution degree 2

IEC/EN 60255-27

Flammability All plastic parts are self-extinguishing to UL94-V0
EMC IEC/EN 60255-26