Generator controller functions

AGC 150 Generator Mains BTB Data sheet

Name
agc-150-generator-mains-btb-data-sheet-4921240618-uk
Product
AGC 150 Mains
AGC 150 BTB
AGC 150 Generator

Genset functions

Synchronising functions Core Extended Premium
Synchronising (dynamic)
Synchronising (static)  
CBE (run up sync)  
Short-time parallel
Generator functions Core Extended Premium
Built-in analogue AVR control
External analogue AVR control via IOM 230
Digital AVR control: Remote configuration, DVC - DEIF
Digital AVR control: Voltage biasing and remote configuration, DVC 550 - DEIF
Digital AVR control: Voltage biasing, Nidec D550
Digital AVR control: Voltage biasing and remote configuration, Nidec D550    
Step-up transformer (with phase angle compensation)  
Communication with KWG ISO5 isolation monitor (CAN bus)
Advanced AC protections Core Extended Premium
Vector shift  
ROCOF (df/dt)  
Under-voltage and reactive power, U and Q  
Average busbar over-voltage  
AC directional over-current protection  
Negative sequence current (ANSI 46I2)  
Negative sequence voltage (ANSI 47)  
Zero sequence current (ANSI 51I0)  
Zero sequence voltage (ANSI 59U0)  
Power-dependent reactive power (ANSI 40)  
Inverse time over-current (ANSI 51)  
Grid support (frequency-dependent droop)    
Ground relay  
4th current transformer measurement Core Extended Premium
High current alarms 2 2 2
High reverse alarms 2 2 2
High power alarms 2 2 2
Additional genset modes Core Extended Premium
Ventilation
Dry alternator
Load sharing Core Extended Premium
Equal load sharing via power management
Analogue load sharing (with IOM 230)
Digital load sharing (CANshare)
3rd party load sharing

Engine functions

Start and stop functions Core Extended Premium
Engine start and stop sequences
Temperature-dependent cooling down
Time-based cooling down
Configurable crank and run coil
Regulation functions Core Extended Premium
Governor regulation using:
  • Engine communication
  • Built-in analogue control
  • External analogue control using IOM 230
  • Relays
Manual speed control using:
  • Digital inputs
  • Display screen menu (by the operator)
  • Analogue input
  • Modbus
  • Configured set point
Speed sensing using CAN, MPU or frequency
Derate engine  
Ventilation fan control  
Power ramp up and down
Engine protections Alarms ANSI Operate time
Overspeed 2 12 <400 ms
Crank failure 1 48  
Running feedback error 1 34  
MPU wire break 1 -  
Start failure 1 48  
Stop failure 1 -  
Stop coil, wire break alarm 1 -  
Engine heater 1 26  
Max. ventilation/radiator fan 1 -  
Fuel fill check 1 -  
Maintenance alarms Multiple    
Other engine functions Core Extended Premium
Fuel usage monitoring
Fuel pump logic and refill
Diesel exhaust fluid monitoring
Diesel exhaust fluid logic and refill
Generic fluid monitoring
Generic fluid logic and refill